General and Medical Chemistry Lab 6: titration
A student's report from Exercise 6 (the lab manual's report, page 35) and their answers to its questions, typed and checked. One calculation slip is corrected below.
Issues to be prepared
The neutralisation reaction. Acid + base → salt + water. Between strong acids and bases the net ionic reaction is always the same: H⁺ + OH⁻ → H₂O (ΔH ≈ −57 kJ/mol), with the other ions as spectators (HCl + NaOH → NaCl + H₂O). A weak acid reacts in its molecular form: CH₃COOH + OH⁻ → CH₃COO⁻ + H₂O.
pH of aqueous solutions of acids and bases. pH = −log[H⁺], pOH = −log[OH⁻], pH + pOH = 14 (25 °C).
- Strong acid: [H⁺] = c. 0.1 M HCl: pH = 1.0. 0.01 M HCl: pH = 2.0.
- Strong base: [OH⁻] = c. 0.1 M NaOH: pOH = 1, pH = 13.0.
pH of solutions of weak acids and bases. They dissociate only partly, so [H⁺] is set by K_a:
- Weak acid: [H⁺] = √(K_a·c), so pH = ½pK_a − ½log c. 0.1 M CH₃COOH (pK_a 4.76): pH = 2.38 + 0.5 = 2.88.
- Weak base: [OH⁻] = √(K_b·c), so pOH = ½pK_b − ½log c. 0.1 M NH₃ (pK_b 4.75): pOH = 2.88, pH = 11.12.
- The shortcut holds when the acid is under about 5% dissociated (c/K_a above about 400).
pH of salt solutions (hydrolysis). The ion of a weak acid or weak base reacts with water.
| Salt made from | Example | Hydrolysis | Solution | pH formula and example |
|---|---|---|---|---|
| Strong acid + strong base | NaCl, KNO₃ | none | neutral, pH 7 | – |
| Weak acid + strong base | CH₃COONa, Na₂CO₃ | CH₃COO⁻ + H₂O ⇌ CH₃COOH + OH⁻ | alkaline | pH = 7 + ½pK_a + ½log c; 0.1 M CH₃COONa: 7 + 2.38 − 0.5 = 8.88 |
| Strong acid + weak base | NH₄Cl | NH₄⁺ + H₂O ⇌ NH₃ + H₃O⁺ | acidic | pH = 7 − ½pK_b − ½log c; 0.1 M NH₄Cl: 7 − 2.38 + 0.5 = 5.12 |
| Weak acid + weak base | CH₃COONH₄ | both ions | depends on K_a vs K_b | pH = 7 + ½(pK_a − pK_b); CH₃COONH₄ ≈ 7.0 |
This is why the pH at the equivalence point of a titration is not always 7.
Acid-base indicators. Weak organic acids (HIn) whose acid and base forms differ in colour. The colour changes over about pK_In ± 1.
| Indicator | Range (pH) | Acid → base colour | Used for |
|---|---|---|---|
| Methyl orange | 3.1–4.4 | red → yellow (orange at the end point) | strong acid titrating a weak base, or carbonate (6.1) |
| Methyl red | 4.4–6.2 | red → yellow | strong acid titrating a weak base (NH₃) |
| Bromothymol blue | 6.0–7.6 | yellow → blue | strong acid with strong base (pH 7) |
| Phenolphthalein | 8.2–10.0 | colourless → raspberry pink | weak acid titrated with strong base; also strong-strong (6.2) |
The indicator must change colour within the steep jump of the titration curve; its pK_In should be close to the pH at the equivalence point.
Types of titration.
- By the reaction in the solution:
- acid-base (alkacymetry: acidimetry determines bases with a standard acid, alkalimetry determines acids with a standard base), as in 6.1 and 6.2;
- redox (manganometry with KMnO₄ as in 6.3, iodometry, dichromatometry);
- precipitation (argentometry with AgNO₃, e.g. the Mohr method for chloride);
- complexometric (EDTA, e.g. Ca²⁺ and Mg²⁺, water hardness).
- By the way of titrating: direct (titrant straight into the analyte); back titration (an excess of a standard reagent is added and the unreacted remainder is titrated); substitution (displacement) titration (the analyte releases an equivalent amount of another substance, which is titrated, e.g. iodometry).
- By how the end point is detected: visual (an indicator, or the titrant's own colour as with KMnO₄), potentiometric (a pH meter or electrode), conductometric (6.4).
End point and equivalence point.
- The equivalence point is the theoretical point where the amount of titrant added is chemically equivalent to the analyte (in the stoichiometric ratio of the equation).
- The end point is the point actually observed, where the indicator changes colour and the titration is stopped.
- The difference between the two is the titration error; choosing the right indicator keeps it small.
The acid-base titration curve. A plot of pH (vertical) against the volume of titrant added (horizontal). Its shape: a slow change, then a steep jump around the equivalence point, then a slow change again.
- Strong acid with strong base (HCl with NaOH, 0.1 M): starts at pH 1, jumps from about pH 4 to 10, equivalence point at pH 7. Any of the indicators above works.
- Weak acid with strong base (CH₃COOH with NaOH): starts higher (pH 2.9) and rises through a buffer region; at half-neutralisation pH = pK_a; the jump is shorter (about 7.5–10) and the equivalence point is alkaline (about 8.7). Use phenolphthalein.
- Weak base with strong acid (NH₃ with HCl): equivalence point acidic (about 5.3). Use methyl red or methyl orange.
- Na₂CO₃ with HCl (6.1): two steps and two equivalence points: CO₃²⁻ → HCO₃⁻ at about pH 8.3 (phenolphthalein), then HCO₃⁻ → H₂CO₃ (CO₂) at about pH 4 (methyl orange). Titrating to the methyl orange end point measures both, hence the 1 : 2 ratio.
Concepts: analyte, titrant.
- The analyte (titrand) is the substance whose amount or concentration is being determined; it is in the conical flask.
- The titrant is the solution of exactly known concentration (a standard solution) added from the burette.
- A primary standard is a pure, stable, non-hygroscopic substance that can be weighed exactly, such as anhydrous Na₂CO₃ (6.1), borax or oxalic acid. Finding the exact concentration of a titrant against it is standardisation; the standardised HCl then serves to determine NaOH (6.2).
- The calculation always runs: moles of titrant = c × V → moles of analyte by the ratio in the equation → concentration = moles ÷ the analyte's volume.
6.1 Standardising hydrochloric acid with sodium carbonate
- Na₂CO₃ + 2HCl → 2NaCl + H₂O + CO₂↑: one mole of carbonate takes two of acid.
- The weighed Na₂CO₃ is dissolved completely in water and methyl orange is added: the solution is yellow. The HCl from the burette turns it, gradually, from yellow to orange at the end point.
- Burette readings were 20, 24 and 22 cm³, a mean of 22.0 cm³ = 0.0220 dm³. Repeat titrations should agree within about 0.1–0.2 cm³; three this far apart mean a rough first run to discard.
- n(Na₂CO₃) = 0.1 g ÷ 106 g/mol = 9.43 × 10⁻⁴ mol. n(HCl) = 2 × 9.43 × 10⁻⁴ = 1.89 × 10⁻³ mol.
- c(HCl) = 1.89 × 10⁻³ mol ÷ 0.0220 dm³ = 0.086 mol/dm³, close to the expected 0.1 M.
- Correction: the report's "C = 0.00094 mol/dm³" is not a concentration. 0.00094 is the amount of Na₂CO₃ in moles; the acid's concentration is n(HCl) ÷ V(HCl) = 0.086 mol/dm³.
6.2 Sodium hydroxide against the standard acid
- NaOH + HCl → NaCl + H₂O, one to one.
- 10.0 cm³ of the NaOH with phenolphthalein is pink. Titrated with the 0.086 M HCl, it turns colourless at the end point.
- n(HCl) = 0.086 × 0.0130 dm³ = 1.12 × 10⁻³ mol = n(NaOH).
- c(NaOH) = 1.12 × 10⁻³ ÷ 0.0100 dm³ = 0.112 mol/dm³.
6.3 Hydrogen peroxide by manganometry
- 2KMnO₄ + 3H₂SO₄ + 5H₂O₂ → K₂SO₄ + 2MnSO₄ + 8H₂O + 5O₂↑. In acid, MnO₄⁻ takes five electrons to Mn²⁺, and each H₂O₂ gives two electrons as it becomes O₂.
- The purple permanganate is decolourised as it reacts. The end point is the first pale pink that lasts for a few seconds: KMnO₄ is its own indicator.
- 10.0 cm³ of the peroxide sample took a mean 13.0 cm³ of 0.02 M KMnO₄.
- n(KMnO₄) = 0.02 × 0.0130 = 2.60 × 10⁻⁴ mol, and n(H₂O₂) = 5/2 × 2.60 × 10⁻⁴ = 6.50 × 10⁻⁴ mol.
- c(H₂O₂) = 6.50 × 10⁻⁴ ÷ 0.0100 dm³ = 0.065 mol/dm³.
The report's questions
- Manganometry: a redox titration with potassium permanganate as the titrant. KMnO₄ is a strong oxidising agent, and its colour change marks the end point.
- Strong electrolytes: HCl, NaOH, HNO₃. Weak: NH₃, H₂S, CH₃COOH.
- Electrolytic dissociation: an electrolyte splits into positive and negative ions when dissolved in water or molten, so the solution conducts electricity, for example NaCl → Na⁺ + Cl⁻.
- Adding a salt raises the conductivity: NaCl dissociates into more ions to carry the current.
- Equivalence point: where chemically equivalent amounts of titrant and analyte have reacted. End point: the point seen in the experiment, where the indicator changes and the titration stops. A well-chosen indicator makes the two coincide.
6.4 Conductometric titration
The manual's 6.4 determines hydrochloric acid by conductometric titration: instead of an indicator, the electrical conductivity of the solution is measured after each portion of titrant (NaOH) is added. The manual's own steps for this part were not in the photos, so this follows the standard method: a conductivity cell in the HCl, NaOH added in equal portions (for example 0.5 cm³), the conductivity read after each one and plotted against the volume.
Why the conductivity changes. It depends on how many ions there are and how fast they move. H⁺ and OH⁻ move far faster than any other ion, because they pass along chains of water molecules by proton hopping (the Grotthuss mechanism). Typical limiting molar conductivities at 25 °C, in S·cm²/mol:
| Ion | H⁺ | OH⁻ | Cl⁻ | Na⁺ |
|---|---|---|---|---|
| Molar conductivity | 350 | 199 | 76 | 50 |
The shape of the curve: a V.
- Before the equivalence point: H⁺ + Cl⁻ + Na⁺ + OH⁻ → Na⁺ + Cl⁻ + H₂O. Each added OH⁻ removes a fast H⁺ and puts a slow Na⁺ in its place, so the conductivity falls steeply in a straight line.
- At the equivalence point: only Na⁺ and Cl⁻ remain (an NaCl solution), and the conductivity is at its minimum (not zero).
- After the equivalence point: excess NaOH adds both Na⁺ and fast OH⁻, so the conductivity rises again in a straight line, less steeply than it fell, because OH⁻ is slower than H⁺.
- The equivalence point is read as the intersection of the two straight lines, extrapolated from points away from the minimum (the curve is rounded right at the bottom).
- The calculation is then as in 6.2: c(HCl) = c(NaOH) × V_eq ÷ V(HCl).
Practical points.
- The titrant should be about ten times more concentrated than the analyte, so the volume hardly changes and the branches stay straight; otherwise the readings are corrected by multiplying by (V₀ + V) / V₀.
- The advantages: no indicator is needed, so coloured or turbid solutions and very dilute ones can be titrated, and weak acids give a usable curve (rising from a low start, with a sharp bend at the equivalence point) where an indicator gives a poor end point.
- Conclusion: the conductivity fell to a minimum and then rose again (a V-shaped curve); the volume of NaOH at the intersection of the two lines is the equivalence point, from which the HCl concentration is calculated.