General and Medical Chemistry Lab 12: proteins
Preparation for Exercise 12 of the lab manual: dialysis, the UV spectrum of a protein, the biuret determination of serum protein with its standard curve, salting out of egg-white proteins, and the issues to be prepared.
Issues to be prepared
Higher-order structure of proteins.
- Secondary structure: the local folding of the backbone, held by hydrogen bonds between C=O and N–H of peptide bonds.
- α-helix: right-handed, 3.6 residues per turn, 0.54 nm pitch. The C=O of residue n bonds to the N–H of residue n + 4, and the side chains point outwards. Proline breaks it.
- β-pleated sheet: extended strands side by side, parallel or antiparallel, with H-bonds between the strands.
- β-turns (often glycine and proline) and loops join the helices and strands.
- Tertiary structure: the 3-D fold of the whole chain. It is held by side-chain interactions: hydrophobic interactions (non-polar side chains buried inside), hydrogen bonds, ionic bonds (salt bridges, e.g. Lys⁺ with Asp⁻), van der Waals forces and covalent disulfide bridges (–S–S– between two cysteines).
- Quaternary structure: two or more subunits joined by the same non-covalent bonds (sometimes by disulfides). Examples: haemoglobin α₂β₂, LDH H/M tetramers, immunoglobulins (2 heavy + 2 light chains, joined by disulfides).
- Denaturation destroys the secondary, tertiary and quaternary structure but leaves the peptide bonds (the primary structure). The causes are heat, extremes of pH, heavy-metal ions, urea, detergents and organic solvents. Activity is lost; solubility usually falls.
Biological functions of proteins.
| Function | Examples |
|---|---|
| Catalysis | enzymes (amylase, LDH, DNA polymerase) |
| Transport | haemoglobin (O₂), albumin (fatty acids, bilirubin, drugs), transferrin (Fe³⁺), lipoproteins |
| Structure | collagen, elastin, keratin |
| Movement | actin, myosin |
| Defence | immunoglobulins, complement, fibrinogen (clotting) |
| Regulation | hormones (insulin, glucagon), receptors, transcription factors |
| Storage | ferritin (iron), casein |
| Osmotic pressure and pH | albumin keeps the plasma oncotic pressure; plasma proteins are buffers |
Physicochemical properties of proteins.
- Amphoteric: free –COOH and –NH₂ groups at the chain ends and in the side chains (Asp, Glu, Lys, Arg, His). At the isoelectric point (pI) the net charge is zero. Above the pI the protein is negative, below it positive. Most plasma proteins have a pI under 7.4, so they are anions in blood (albumin pI ≈ 4.7).
- Colloids: proteins are macromolecules (10–1000 kDa). They do not pass through semipermeable membranes (the basis of dialysis and of the oncotic pressure), they scatter light (Tyndall effect) and they do not crystallise easily.
- Solubility depends on the hydration shell and on the charge (like charges repel). It is lowest at the pI. Small amounts of salt raise it (salting in); high salt lowers it (salting out).
- UV absorption: peptide bonds absorb at 190–230 nm; Trp and Tyr give a band at 280 nm.
- Denaturation and precipitation (salting out, heavy-metal ions, alkaloid reagents, organic solvents, strong acids). Salting out is reversible; the others mostly denature.
12.1 Dialysis
The principle. A dialysis bag is a semipermeable membrane (cellophane/cellulose) with pores that let small molecules and ions through but hold back macromolecules. Small solutes diffuse down their concentration gradient into the water outside the bag; the protein stays inside. The rate depends on the concentration difference, membrane area and permeability, and temperature. In the laboratory dialysis is used to desalt protein solutions, for example after salting out, or to change the buffer.
The setup. Inside the bag: 10 cm³ of a mixture of protein (0.5% gelatin), 10% glucose and 0.9% NaCl. Outside: distilled water, stirred now and then for 1.5 hours. Solution 1 = inside the bag, solution 2 = the water outside.
The tests.
- Cl⁻: a few drops of 0.1 M AgNO₃. Ag⁺ + Cl⁻ → AgCl↓ (white, curdy precipitate).
- Glucose: Molisch's test, 20% α-naphthol, then concentrated H₂SO₄ down the side. A positive result is a red-violet ring at the boundary.
- Protein: the biuret test, NaOH and a little 0.5% CuSO₄. Positive is violet; negative stays light blue (Cu(OH)₂ colour).
The expected results.
| Test | Solution 1 (inside the bag) | Solution 2 (water outside) |
|---|---|---|
| Cl⁻ (AgNO₃) | + (white AgCl) | + (white AgCl) |
| Glucose (Molisch) | + (violet ring) | + (violet ring) |
| Protein (biuret) | + (violet) | − (blue) |
The tests inside the bag are still positive for Cl⁻ and glucose because 1.5 hours is not enough for complete equilibrium. The precipitate and ring are weaker than at the start.
Conclusion: Cl⁻ and glucose (small molecules) passed through the membrane into the water; the protein (a macromolecule) did not. Dialysis separates proteins from small molecules and is used to desalt protein solutions.
12.2 The UV spectrum of a protein
The principle. Proteins absorb ultraviolet light through:
- the peptide bonds: an intense band in the far UV, maximum about 190–230 nm (the 205–220 nm region is used to measure all proteins).
- the aromatic amino acids: a band in the near UV with a maximum at about 280 nm, mostly from tryptophan (ε ≈ 5,600 M⁻¹ cm⁻¹) and tyrosine (ε ≈ 1,400 M⁻¹ cm⁻¹). Phenylalanine absorbs weakly at about 257 nm. Disulfide bonds absorb weakly near 250–260 nm.
- Because the absorbance at 280 nm depends on the amino acid composition, every protein has its own spectrum. It also depends on structure, pH and ionic strength.
Absorbance follows the Beer–Lambert law: A = ε × c × l.
- A is the absorbance (no units), ε the absorption coefficient, c the concentration and l the cuvette path (1 cm).
- For BSA, A₂₈₀ of a 1 mg/cm³ solution is about 0.66.
The procedure. BSA and gelatin, 1 mg/cm³, are diluted 10 times in 0.9% NaCl (to 0.1 mg/cm³). The absorbance is read every 5 nm from 200 to 300 nm in quartz cuvettes (glass and plastic absorb UV), against 0.9% NaCl. Plot A against λ.
The expected spectra (illustrative values for 0.1 mg/cm³):
| λ (nm) | BSA | Gelatin |
|---|---|---|
| 210–220 | very high, often over 2 (off scale) | very high, often over 2 |
| 230 | about 0.5–1 | about 0.4–0.8 |
| 250 | minimum, about 0.03 | about 0.02 |
| 280 | peak, about 0.07 | about 0.01 (no peak) |
| 300 | about 0 | about 0 |
- BSA: a steep rise below 240 nm (peptide bonds), a trough at about 250 nm and a clear peak at about 278–280 nm (2 Trp and about 20 Tyr per molecule).
- Gelatin: the same peptide-bond rise below 240 nm, but almost no 280 nm band. Gelatin comes from collagen. It has no tryptophan and very little tyrosine; it is mostly Gly, Pro and hydroxyproline.
Conclusion: both proteins absorb strongly below 230 nm because of their peptide bonds. Only BSA shows the 280 nm band, because it contains tryptophan and tyrosine. The UV spectrum depends on a protein's amino acid composition, and A₂₈₀ can only be used to measure proteins that contain aromatic amino acids.
12.3 Quantitative determination of protein: the biuret method
The principle. In a strongly alkaline solution, Cu²⁺ forms a violet complex with the nitrogen atoms of the peptide bonds: each Cu²⁺ binds 4 peptide nitrogens from neighbouring bonds. The colour (λ max about 540–550 nm; read at λ = 550 nm) is proportional to the number of peptide bonds, and so to the protein concentration.
- The biuret reagent contains CuSO₄ and NaOH, with sodium potassium tartrate to keep Cu²⁺ in solution (no Cu(OH)₂ precipitate) and KI to stop Cu²⁺ being reduced.
- At least two peptide bonds are needed, so tripeptides and longer react. Free amino acids and dipeptides do not. The name comes from biuret (H₂N–CO–NH–CO–NH₂), which gives the same colour.
- The method is simple and nearly independent of the amino acid composition, but has low sensitivity (about 1–10 mg of protein per test).
The standard curve (the manual's scheme). Tubes 0 to 10 get the 10 mg/cm³ BSA and 0.9% NaCl as below. A twelfth tube holds 0.1 cm³ of serum + 0.9 cm³ of 0.9% NaCl (the serum diluted 10 times).
| Tube | 10 mg/cm³ BSA (cm³) | 0.9% NaCl (cm³) | Protein concentration (mg/cm³) | A₅₅₀ (illustrative) |
|---|---|---|---|---|
| 0 | 0 | 1.0 | 0 | 0 (the blank) |
| 1 | 0.1 | 0.9 | 1 | 0.040 |
| 2 | 0.2 | 0.8 | 2 | 0.080 |
| 3 | 0.3 | 0.7 | 3 | 0.120 |
| 4 | 0.4 | 0.6 | 4 | 0.160 |
| 5 | 0.5 | 0.5 | 5 | 0.200 |
| 6 | 0.6 | 0.4 | 6 | 0.240 |
| 7 | 0.7 | 0.3 | 7 | 0.280 |
| 8 | 0.8 | 0.2 | 8 | 0.320 |
| 9 | 0.9 | 0.1 | 9 | 0.360 |
| 10 | 1.0 | 0 | 10 | 0.400 |
- Filling in the concentration row: concentration = volume of BSA × 10 mg/cm³ ÷ 1 cm³. Tube 4: 0.4 × 10 / 1 = 4 mg/cm³.
- Add 4 cm³ of biuret reagent to all 12 tubes. Mix and leave for 30 minutes.
- Read each tube at λ = 550 nm against tube 0.
- Plot the calibration curve: protein concentration (mg/cm³) on the x-axis, absorbance on the y-axis. It should be a straight line through the origin.
The calculation. Read the concentration of the serum tube off the curve (or divide its absorbance by the slope). Then multiply by 10, the dilution of the serum.
- A worked example: the serum tube reads A = 0.276. The slope is 0.040 per mg/cm³, so the diluted serum holds 0.276 / 0.040 = 6.9 mg/cm³.
- The serum itself: 6.9 × 10 = 69 mg/cm³ = 69 g/l (6.9 g/dl).
- The absorbances are illustrative. Use your own curve.
The normal range. Total serum protein in adults is 60–80 g/l (6.0–8.0 g/dl); albumin 35–50 g/l. Use the class range if it differs.
- High (hyperproteinaemia): dehydration (relative), multiple myeloma and other monoclonal gammopathies, chronic inflammation and chronic liver disease (polyclonal γ-globulins).
- Low (hypoproteinaemia): malnutrition and malabsorption, liver failure (less albumin made), nephrotic syndrome (loss in urine), burns, protein-losing enteropathy, overhydration. Low protein lowers the oncotic pressure and causes oedema.
Conclusion: the standard curve is linear in the range used, so the biuret colour is proportional to the protein. The serum protein (your value) is within, or outside, the range of 60–80 g/l.
12.4 Protein salting out
The principle.
- Proteins stay dissolved because of their hydration shell and their surface charge.
- At low salt concentration solubility rises (salting in): the ions shield the attractions between protein molecules.
- At high salt concentration the salt ions take the water of hydration and neutralise the surface charges. The protein molecules aggregate and precipitate (salting out).
- Salting out is reversible. The protein is not denatured: it dissolves again on dilution with water, or after dialysis, and keeps its biological activity. This is why it is used to fractionate and purify proteins, and why dialysis (12.1) follows to remove the salt.
- Each protein precipitates at its own salt concentration.
- Globulins lose their hydration shell already at 50% saturation with (NH₄)₂SO₄, or in saturated MgSO₄ or Na₂SO₄.
- Albumins hold water more strongly (smaller, more charged, more hydrated). They come out only when the solution is fully saturated with (NH₄)₂SO₄.
- The manual's background figures for plasma: 60–80 mg/cm³ of protein, of which 50–60% is albumin and the rest globulins and fibrinogen (3–6 mg/cm³). Plasma proteins are classified by these solubility differences and by their electrophoretic separation (Lab 13). The exercise itself uses egg white, which contains ovalbumin (the main protein) and globulins (e.g. ovoglobulins, lysozyme).
The procedure (the manual's steps) and expected results.
- 10 cm³ of egg white + 10 cm³ of saturated (NH₄)₂SO₄ in a conical flask. Mix and leave a few minutes. This is 50% saturation: a white precipitate of globulins forms.
- Filter. Keep the globulin precipitate. Pour the filtrate, which still holds the albumin, into a new beaker.
- Sprinkle crystalline (NH₄)₂SO₄ into the filtrate in small portions, stirring hard after each and waiting a few minutes. Stop when the salt no longer dissolves (full saturation). A white precipitate of albumin forms.
- Filter and put the albumin precipitate in a new beaker.
- Check the solubility in water of the globulin precipitate and the albumin precipitate separately.
What the water test shows.
- Albumin dissolves readily in distilled water. It is water-soluble by definition, and salting out has not denatured it.
- Globulins dissolve poorly in pure water (the true globulins, euglobulins, need dilute salt to dissolve). The precipitate may only partly dissolve, or give a turbid solution. It dissolves better because some ammonium sulfate is carried over with it, or when a little NaCl is added.
- Both dissolve again, so neither was denatured.
Conclusion: egg-white globulins precipitated at 50% saturation with ammonium sulfate and albumin only at full saturation, because albumin is more strongly hydrated. Albumin dissolved again in water; globulins dissolved poorly in pure water but better with salt. Salting out is reversible, does not denature proteins and separates albumins from globulins by their different solubility.
Salting out compared with denaturing precipitation.
| Agent | Reversible? | Why |
|---|---|---|
| Neutral salts at high concentration ((NH₄)₂SO₄, NaCl, MgSO₄) | yes | removes the hydration shell and charge |
| Ethanol, acetone in the cold | partly | lowers the dielectric constant |
| Heavy-metal ions (Pb²⁺, Hg²⁺, Cu²⁺, Ag⁺) | no | bind –SH and –COO⁻ groups |
| Strong acids, trichloroacetic acid, sulfosalicylic acid | no | denature; insoluble salts |
| Heat | no | breaks non-covalent bonds |
The report's conclusions
- 12.1: Cl⁻ (white AgCl) and glucose (violet Molisch ring) were found in the water outside the bag; protein (biuret violet) only inside. Small molecules pass the semipermeable membrane; proteins do not.
- 12.2: both proteins absorb strongly below 230 nm (peptide bonds). BSA has a peak at about 280 nm (Trp, Tyr); gelatin has almost none, because it lacks tryptophan and is poor in tyrosine.
- 12.3: a linear calibration curve of A₅₅₀ against BSA concentration. The serum total protein is the value read off the curve × 10, in g/l, compared with 60–80 g/l.
- 12.4: egg-white globulins precipitated at 50% saturation with ammonium sulfate and albumin at full saturation. Albumin dissolved in water and globulins only poorly, so the two differ in solubility and salting out is reversible.